We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand UAE. The private labels and part numbers shown on this website are the property of their respective owners.
Model | GT-72A | |
Type | Amplifier unit | |
Output | NPN output | |
Mounting type | DIN rail mount*1 | |
Main unit/Expansion unit | Expansion unit*2 | |
Power consumption | Normal | At 12 V: 1,140 mW (95 mA) or less, At 24 V: 1,200 mW (50 mA) or less |
Power saving (Eco) | At 12 V: 600 mW (50 mA) or less, At 24 V: 840 mW (35 mA) or less | |
Display power | Measured value display | 6-digit 7-segment LED (red) |
Other displays | 2-colour 13-level bar LED display (red, green), indicators (red, green) | |
Display range | -99.999 to 999.999 | |
Display resolution | 1 µm | |
Sampling rate | 2,000 times/second | |
Control input | Timing/preset/bank input | Timing input: Non-voltage input (relay contact, solid state), input time: 2 ms or more Preset/Bank input: Non-voltage input (relay contact, solid state), input time: 20 ms or more |
Response time | hsp (1.5 ms) , 5 ms, 10 ms, 100 ms, 500 ms, 1 s, 5 s | |
HIGH, GO, LOW output | NPN Offenkollektor, max. 50 mA (40 V oder weniger), Restspannung: 1 V oder weniger, N.O./N.C. umschaltbar | |
Major functions | Preset, Hold, Variable hysteresis, Variable response time, Multiplier setting, Bank function (4 banks), Self-timing, Power save (eco) mode, Application mode, Calibration function, Core alarm | |
Rating | Power voltage | 12 to 24 VDC, Ripple (P-P) 10 % or less*3 |
Environmental resistance | Ambient temperature | -10 to +55 °C (No freezing) |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Material | Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: Polycarbonate, Cable: PVC | |
Accessories | Instruction manual | |
Weight | Approx. 110 g (including the power cable) | |
*1 Be sure to mount the DIN rail mounting amplifier on a DIN rail (i.e. the unit should be mounted on the metal DIN plate itself). For additional amplifier unit installation, be sure to use the end unit (OP-26751). *2 One main unit and nine expansion units (ten in total) can be additionally installed. For additional amplifier unit installation, each output current must be 20 mA or less. *3 If additional amplifier units are installed, the power supply voltage is 24 VDC. |