Application | |||||||
---|---|---|---|---|---|---|---|
Media | Water, glycol solutions, backlash, oils | ||||||
Medium note |
| ||||||
Measured medium temperature [°C] | -20…100 | ||||||
Pressure strength [bar] | 50 | ||||||
MAWP (for CRN application) [bar] | 50 | ||||||
Electronic data | |||||||
Operating voltage [V] | 18…30 DC | ||||||
Current consumption [mA] | < 100 | ||||||
Protection class | III | ||||||
Reverse polarity protection | yes | ||||||
Power-on delay time [s] | 10 | ||||||
Inputs/outputs | |||||||
Number of inputs and outputs | Number of digital outputs: 2 , Number of analog outputs: 1 | ||||||
Outputs | |||||||
Total number of outputs | 2 | ||||||
Output signal | Switching signal, analogue signal, frequency signal, IO-Link, (configurable) | ||||||
Electric Hard version | PNP/NPN | ||||||
Number of digital outputs | 2 | ||||||
Output function | normally open / normally closed, (parameterizable) | ||||||
Max. voltage drop of switching output DC [V] | 2.5 | ||||||
DC load current of switching output DC [mA] | 250 | ||||||
Number of analog outputs | 1 | ||||||
Analog current output [mA] | 4…20, (scalable) | ||||||
Maximum load [?] | 350 | ||||||
Short-circuit protection | yes | ||||||
Short-circuit protection type | clocked | ||||||
Overcurrent protection | yes | ||||||
Output frequency [Hz] | 0…1000 | ||||||
Measuring/setting range | |||||||
Probe length L [mm] | 100 | ||||||
Operating mode | Relative, Absolute liquid, Absolute gaseous | ||||||
Note on setting range |
| ||||||
Liquid media | |||||||
Measuring range [m/s] | 0.04…3 | ||||||
Setting parameters within [m/s] | 0…6 | ||||||
Gases | |||||||
Measuring range [m/s] | 2…100 | ||||||
Parameter setting within [m/s] | 0… 200 | ||||||
Temperature control | |||||||
Measuring range [°C] | -20… 100 | ||||||
Resolution [°C] | 0.2 | ||||||
Accuracy/Uncertainty | |||||||
Flow rate control | |||||||
Temperature drift [cm/s x 1/K] | 0.003 m /s x 1/K ( 70 °C) | ||||||
Max. environment) [K/min] | 100 | ||||||
Accuracy (in measuring range) | ± (7% MW + 2% MEW), (for relative mode in the measuring range c:, Water: 20…70 °C, inlet pipe length: 1.5 m, DN25 (DIN 2448), installation position according to the instructions, Accuracy may differ for other media and mounting positions.) | ||||||
Repeatability | 0.05 m/s, (Water, Flow velocity: 0.05…3 m/s) | ||||||
Temperature control | |||||||
Temperature drift | ± 0.005 K/°C | ||||||
Accuracy [K] | ± 0.3 / ± 1, (Water, Flow velocity: 0.3…3 m/s / backlash, Flow velocity: > 10 m/s) | ||||||
Reaction time | |||||||
Flow rate control | |||||||
Response time [s] | 0.5, (T09, Water, glycol: 0.8 s, backlash: 7 s, oil: 1.8 s, each T09) | ||||||
Temperature control | |||||||
Trip response time T05 / T09 [s] | 1.5 (T09), (Water, Flow rate: 0, 3…3 m/s) | ||||||
Software / Programming | |||||||
Parameter selection | Hysteresis / window, normally open/normally closed, switching logic, current/frequency output, medium selection, damping, teach-in function, display can be rotated and switched off, standard unit of measure, process value color | ||||||
Interfaces | |||||||
Communication interface | IO-Link | ||||||
Transmission method | COM2 (38.4 kBaud) | ||||||
IO-Link test | 1.1 | ||||||
SDCI standard | IEC 61131-9 | ||||||
IO-Link device ID | 533 d / 00 02 15 h (REL) | ||||||
Profiles | Smart Sensor: Process Data Variable, Device Identification, Device Diagnosis | ||||||
SIO Mode | yes | ||||||
Desired port type | A | ||||||
Analog operating data | 2 | ||||||
Binary operating data | 2 | ||||||
Minimum operating cycle time [ms] | 3 | ||||||
Operating conditions | |||||||
Ambient temperature [°C] | -40…80 | ||||||
Storage temperature [°C] | -40…100 | ||||||
Degree of protection | IP 65, IP 67 | ||||||
Tests / approvals | |||||||
EMC |
| ||||||
Impact resistance |
| ||||||
Vibration resistance |
| ||||||
MTTF [years] | 180 | ||||||
UL Certification |
| ||||||
Mechanical data | |||||||
Weight [g] | 299.5 | ||||||
Material | stainless steel steel (1.4404 / 316L), PBT-GF20, PBT-GF30 medium | stainless steel steel (1.4404 / 316L) | |||||
Process connection | Diameter Ø 8 mm | ||||||
Displays / Control elements | |||||||
Display |
| ||||||
Notes | |||||||
Notes |
| ||||||
Packaging size | 1 piece | ||||||
electrical connection | |||||||
Connection | Connector : 1 x M12, Contacts: gold-plated |