We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand UAE. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
MGB-L1H-ARA-R-110613
Part number
110613
Description
Block Lock Sicherheitstüren
Stock availability:
On request
MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
OT | Bolt tongue inserted in the evaluation module |
OI | Diagnostics, there is a fault |
S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
S2 | 1 NO contact, yellow, illuminated |
S3 | 1 NO contact, white, illuminated |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,00 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN right |
Product version number | V3.0.0 |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0,25 Hz |
Connection | Plug connector RC18 |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Emergency stop | |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Product version number | V3.0.3 |
Slide-in label | 2 pcs. without marking |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Emergency stop | |
B10D | |
Emergency stop | 0,065 x 106 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Mission time | 20 y |