TQ2-0302G024-5000 Euchner 103380
 TQ2-0302G024-5000 Euchner 103380

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand UAE. The private labels and part numbers shown on this website are the property of their respective owners.

Euchner TQ2-0302G024-5000 103380

Manufacturer

Euchner

Country

Germany

Name

TQ2-0302G024-5000

Part number

103380

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications TQ2-0302G024-5000 103380

On website of FAMAGA you can buy TQ2-0302G024-5000, and many other spare parts from the Euchner with delivery all over the United States , including: Dublin.For price list, delivery timings and other product features of the Euchner, please, fill in the feedback form or send a description of goods you need to our e-mail [email protected]

Features TQ2-0302G024-5000 103380

  • Compact housing
  • Mechanical release from 3 sides
  • Any installation position
  • LED indicator
  • connection cable 5m
Guard locking types
TQ2Open-circuit current principle, guard locking by applying voltage to the guard locking solenoid. Release by spring force.
Switching elements
SKFor monitoring the door/actuator position.
UKMonitoring contact for monitoring the guard locking (built-in solenoid).
0302Slow-action switching contact 3 NC + 2 NC
Auxiliary release This releases the guard locking after operation with a triangular key (included).
Housing material Reinforced thermoplastic
Weight
Net 0,5 kg
Ambient temperature -20 ... 50 °C
Degree of protection IP67
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position positively driven contacts 3
Number of guard lock monitoring NC contacts 2
Connection Connection cable 5m
Approach speed 0,05 ... 1 m/min
Actuation frequency 900 1/h
Guard locking principle 3 Open-circuit current principle
Locking force Fmax 500 N
Retention force 1 N
Extraction force 10 N
Actuating force 5 N
Insertion depth 26,3 mm
Electrical connection ratings
Thermal rated current Ith 2,5 A
Utilization category according to EN 60947-5-1
AC-15 0.75A 250V
1A 125V
DC-13 0.27A 250V
0.22A 125V
Solenoid operating voltage
DC 24 V -15% ... +10%
Short circuit protection according to IEC 60269-1
(Fuse) 2A gG
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Power consumption 2,7 W
Solenoid duty cycle 100 %
Reliability values according to EN ISO 13849-1
Monitoring of the position of the safety guard
B10D 2 x 106
In combination with Actuator BETAETIGER-Q-GT, RADIUSBETAETIGER-Q-RO, RADIUSBETAETIGER-Q-LU, BETAETIGER-Q-WTMechanical values and environment
Overtravel A B C D E 1,9 mm
In combination with Actuator BETAETIGER-Q-WTBMechanical values and environment
Overtravel A B C D E 1,3 mm