We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand UAE. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
TQ1-1211G024-5000
Part number
103379
Description
seal 16.0133.170870 170,8x6,99 EPDM 75SH
Stock availability:
On request
TQ1 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
SK | For monitoring the door/actuator position. |
UK | Monitoring contact for monitoring the guard locking (built-in solenoid). |
1211 | Slow-action switching contact 2 NC + 1 NC + 2 NO |
Housing material | Reinforced thermoplastic |
Weight | |
Net | 0,5 kg |
Ambient temperature | -20 ... 50 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | 2 |
Number of door position NO contacts | 1 |
Number of guard lock monitoring NC contacts | 1 |
Number of guard lock monitoring NO contacts | 1 |
Connection | Connection cable 5m |
Approach speed | 0,05 ... 1 m/min |
Actuation frequency | 900 1/h |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 500 N |
Retention force | 1 N |
Extraction force | 10 N |
Actuating force | 5 N |
Insertion depth | 26,3 mm |
Thermal rated current Ith | 2,5 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 0.75A 250V |
1A 125V | |
DC-13 | 0.27A 250V |
0.22A 125V | |
Solenoid operating voltage | |
DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 2A gG |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 2,7 W |
Solenoid duty cycle | 100 % |
Monitoring of the position of the safety guard | |
B10D | 2 x 106 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Overtravel A B C D E | 1,3 mm |
Overtravel A B C D E | 1,9 mm |